Obdaryn

P0E6DBattery Charging System Precharge Contactor Control Circuit/Open

  • Generic OBD-II code · Powertrain
How the car detects it
P0E6D concerns the low-voltage side of the charging precharge contactor: the coil circuit through which the control unit switches it, typically interrupted. Unlike P0E6C, which judges what happens on the high-voltage side, this code comes from the driver output itself. No manufacturer documents P0E6D publicly. GM uses the same method on the positive charging contactor of its 2019 hybrids (P0D0A): an open is recognised when the switched-off output still shows more than 4 V, or when less than 194 mA flows with the output on; 40 failed samples out of 50 at 12.5 ms set a Type B code. Mitsubishi's i-MiEV compares a coil monitor with the command and stores P0AE6 for the charging contactor. Range, low and high faults of the coil circuit are P0E6E to P0E70.
What you may notice
  • Charging cannot be started
  • High-voltage system fault message
Likely causes
  • LikelyBroken coil control wire or unplugged connector
  • PossibleOpen winding in the contactor coil
  • RareFailed driver stage in the battery management unit
Repair
Workshop only · Usually a job for a workshop.Typical cost: €150 – €1,500

Explanation from obdex (CC0), exactly as the app shows it. Guidance only; confirm with a workshop.