Obdaryn

P0A98Hybrid/EV Battery Pack Cooling Fan 2 Stuck On

  • Generic OBD-II code · Powertrain
  • Turns on the check-engine light
  • Matters for the ITP
How the car detects it
P0A98 reports that battery cooling fan 2 keeps running after the controller has commanded it off; it mirrors P0A83 for fan 1. No manufacturer documents this code publicly. CARB calls for fan outputs to be checked for correct response to commands. GM's published method for fan 1 (sense code P0BC8) flags a fan that still reports more than about 250 rpm after being off for over 20 s; the same logic applies to a second fan. Typical causes are a welded relay, a control wire shorted to supply or fan electronics that ignore the stop command. Cooling is not at risk, but the fan can drain the 12 V battery and is audible after shutdown. Fan 2 circuit codes are P0A96, P0A99 and P0A9A.
What you may notice
  • Battery fan audible after the vehicle is switched off
  • 12 V battery discharged after parking
  • Hybrid or check engine warning
Likely causes
  • PossibleWelded fan 2 relay
  • PossibleFan 2 control wire shorted to supply
  • PossibleFan 2 internal controller ignores off command
Inspection (ITP)
Matters for the ITP. While the check-engine light is on, the car fails the emissions check.
Repair
Medium · Usually a job for a workshop.Typical cost: €50 – €700